Table of Orders: separations, locations and lengths
m=order, blz=blaze wavelength, fsr=free spectral range,
d=order separation, l=length of free spectral range, dsp=dispersion
| m | blz (A) | fsr (A) | d (mm) | d (asec) | l (mm) | dsp (A/mm) |
|---|---|---|---|---|---|---|
| 163 | 3505.4 | 21.5 | 0.406 | 11.526 | 10.96 | 1.96 |
| 162 | 3527.0 | 21.8 | 0.403 | 11.434 | 11.03 | 1.97 |
| 161 | 3548.9 | 22.0 | 0.399 | 11.344 | 11.10 | 1.99 |
| 160 | 3571.1 | 22.3 | 0.395 | 11.256 | 11.17 | 2.00 |
| 159 | 3593.6 | 22.6 | 0.392 | 11.167 | 11.24 | 2.01 |
| 158 | 3616.3 | 22.9 | 0.388 | 11.078 | 11.31 | 2.02 |
| 157 | 3639.4 | 23.2 | 0.385 | 10.989 | 11.38 | 2.04 |
| 156 | 3662.7 | 23.5 | 0.381 | 10.902 | 11.45 | 2.05 |
| 155 | 3686.3 | 23.8 | 0.378 | 10.817 | 11.53 | 2.06 |
| 154 | 3710.2 | 24.1 | 0.375 | 10.731 | 11.60 | 2.08 |
| 153 | 3734.5 | 24.4 | 0.371 | 10.646 | 11.68 | 2.09 |
| 152 | 3759.1 | 24.7 | 0.368 | 10.559 | 11.75 | 2.10 |
| 151 | 3784.0 | 25.1 | 0.365 | 10.474 | 11.83 | 2.12 |
| 150 | 3809.2 | 25.4 | 0.361 | 10.393 | 11.91 | 2.13 |
| 149 | 3834.8 | 25.7 | 0.358 | 10.310 | 11.99 | 2.15 |
| 148 | 3860.7 | 26.1 | 0.355 | 10.226 | 12.07 | 2.16 |
| 147 | 3886.9 | 26.4 | 0.352 | 10.142 | 12.15 | 2.18 |
| 146 | 3913.5 | 26.8 | 0.349 | 10.063 | 12.24 | 2.19 |
| 145 | 3940.5 | 27.2 | 0.345 | 9.982 | 12.32 | 2.21 |
| 144 | 3967.9 | 27.6 | 0.342 | 9.898 | 12.41 | 2.22 |
| 143 | 3995.7 | 27.9 | 0.339 | 9.818 | 12.49 | 2.24 |
| 142 | 4023.8 | 28.3 | 0.336 | 9.739 | 12.58 | 2.25 |
| 141 | 4052.3 | 28.7 | 0.333 | 9.660 | 12.67 | 2.27 |
| 140 | 4081.3 | 29.2 | 0.330 | 9.581 | 12.76 | 2.28 |
| 139 | 4110.6 | 29.6 | 0.327 | 9.505 | 12.85 | 2.30 |
| 138 | 4140.4 | 30.0 | 0.324 | 9.426 | 12.95 | 2.32 |
| 137 | 4170.6 | 30.4 | 0.321 | 9.351 | 13.04 | 2.33 |
| 136 | 4201.3 | 30.9 | 0.318 | 9.273 | 13.14 | 2.35 |
| 135 | 4232.4 | 31.4 | 0.315 | 9.195 | 13.23 | 2.37 |
| 134 | 4264.0 | 31.8 | 0.313 | 9.121 | 13.33 | 2.39 |
| 133 | 4296.1 | 32.3 | 0.310 | 9.046 | 13.43 | 2.40 |
| 132 | 4328.6 | 32.8 | 0.307 | 8.970 | 13.54 | 2.42 |
| 131 | 4361.7 | 33.3 | 0.304 | 8.897 | 13.64 | 2.44 |
| 130 | 4395.2 | 33.8 | 0.301 | 8.825 | 13.74 | 2.46 |
| 129 | 4429.3 | 34.3 | 0.299 | 8.749 | 13.85 | 2.48 |
| 128 | 4463.9 | 34.9 | 0.296 | 8.680 | 13.96 | 2.50 |
| 127 | 4499.0 | 35.4 | 0.293 | 8.607 | 14.07 | 2.52 |
| 126 | 4534.7 | 36.0 | 0.291 | 8.535 | 14.18 | 2.54 |
| 125 | 4571.0 | 36.6 | 0.288 | 8.465 | 14.29 | 2.56 |
| 124 | 4607.9 | 37.2 | 0.285 | 8.393 | 14.41 | 2.58 |
| 123 | 4645.3 | 37.8 | 0.283 | 8.325 | 14.53 | 2.60 |
| 122 | 4683.4 | 38.4 | 0.280 | 8.256 | 14.64 | 2.62 |
| 121 | 4722.1 | 39.0 | 0.278 | 8.187 | 14.77 | 2.64 |
| 120 | 4761.5 | 39.7 | 0.275 | 8.120 | 14.89 | 2.66 |
| 119 | 4801.5 | 40.3 | 0.273 | 8.051 | 15.01 | 2.69 |
| 118 | 4842.2 | 41.0 | 0.270 | 7.983 | 15.14 | 2.71 |
| 117 | 4883.6 | 41.7 | 0.268 | 7.920 | 15.27 | 2.73 |
| 116 | 4925.7 | 42.5 | 0.265 | 7.854 | 15.40 | 2.76 |
| 115 | 4968.5 | 43.2 | 0.263 | 7.787 | 15.54 | 2.78 |
| 114 | 5012.1 | 44.0 | 0.261 | 7.724 | 15.67 | 2.81 |
| 113 | 5056.4 | 44.7 | 0.258 | 7.659 | 15.81 | 2.83 |
| 112 | 5101.6 | 45.5 | 0.256 | 7.596 | 15.95 | 2.86 |
| 111 | 5147.5 | 46.4 | 0.254 | 7.535 | 16.10 | 2.88 |
| 110 | 5194.3 | 47.2 | 0.252 | 7.474 | 16.24 | 2.91 |
| 109 | 5242.0 | 48.1 | 0.249 | 7.413 | 16.39 | 2.93 |
| 108 | 5290.5 | 49.0 | 0.247 | 7.350 | 16.54 | 2.96 |
| 107 | 5340.0 | 49.9 | 0.245 | 7.292 | 16.70 | 2.99 |
| 106 | 5390.4 | 50.9 | 0.243 | 7.234 | 16.86 | 3.02 |
| 105 | 5441.7 | 51.8 | 0.241 | 7.176 | 17.02 | 3.05 |
| 104 | 5494.0 | 52.8 | 0.239 | 7.118 | 17.18 | 3.07 |
| 103 | 5547.4 | 53.9 | 0.237 | 7.064 | 17.35 | 3.10 |
| 102 | 5601.7 | 54.9 | 0.235 | 7.007 | 17.52 | 3.14 |
| 101 | 5657.2 | 56.0 | 0.233 | 6.951 | 17.69 | 3.17 |
| 100 | 5713.8 | 57.1 | 0.231 | 6.898 | 17.87 | 3.20 |
| 99 | 5771.5 | 58.3 | 0.229 | 6.845 | 18.05 | 3.23 |
| 98 | 5830.4 | 59.5 | 0.227 | 6.792 | 18.23 | 3.26 |
| 97 | 5890.5 | 60.7 | 0.225 | 6.744 | 18.42 | 3.30 |
| 96 | 5951.9 | 62.0 | 0.223 | 6.694 | 18.61 | 3.33 |
| 95 | 6014.5 | 63.3 | 0.221 | 6.644 | 18.81 | 3.37 |
| 94 | 6078.5 | 64.7 | 0.220 | 6.596 | 19.01 | 3.40 |
| 93 | 6143.8 | 66.1 | 0.218 | 6.549 | 19.21 | 3.44 |
| 92 | 6210.6 | 67.5 | 0.216 | 6.506 | 19.42 | 3.48 |
| 91 | 6278.9 | 69.0 | 0.215 | 6.464 | 19.63 | 3.51 |
| 90 | 6348.6 | 70.5 | 0.213 | 6.419 | 19.85 | 3.55 |
| 89 | 6420.0 | 72.1 | 0.212 | 6.376 | 20.08 | 3.59 |
| 88 | 6492.9 | 73.8 | 0.210 | 6.340 | 20.30 | 3.63 |
| 87 | 6567.6 | 75.5 | 0.209 | 6.300 | 20.54 | 3.68 |
| 86 | 6643.9 | 77.3 | 0.208 | 6.262 | 20.78 | 3.72 |
| 85 | 6722.1 | 79.1 | 0.206 | 6.229 | 21.02 | 3.76 |
| 84 | 6802.1 | 81.0 | 0.205 | 6.194 | 21.27 | 3.81 |
| 83 | 6884.1 | 82.9 | 0.204 | 6.164 | 21.53 | 3.85 |
| 82 | 6968.0 | 85.0 | 0.203 | 6.137 | 21.79 | 3.90 |
| 81 | 7054.0 | 87.1 | 0.202 | 6.109 | 22.06 | 3.95 |
| 80 | 7142.2 | 89.3 | 0.201 | 6.080 | 22.33 | 4.00 |
| 79 | 7232.6 | 91.6 | 0.200 | 6.059 | 22.62 | 4.05 |
| 78 | 7325.4 | 93.9 | 0.199 | 6.039 | 22.91 | 4.10 |
| 77 | 7420.5 | 96.4 | 0.199 | 6.023 | 23.20 | 4.15 |
| 76 | 7518.1 | 98.9 | 0.198 | 6.012 | 23.51 | 4.21 |
| 75 | 7618.4 | 101.6 | 0.198 | 5.994 | 23.82 | 4.26 |
| 74 | 7721.3 | 104.3 | 0.197 | 5.984 | 24.14 | 4.32 |
| 73 | 7827.1 | 107.2 | 0.197 | 5.981 | 24.48 | 4.38 |
| 72 | 7935.8 | 110.2 | 0.197 | 5.979 | 24.82 | 4.44 |
| 71 | 8047.6 | 113.3 | 0.197 | 5.980 | 25.16 | 4.50 |
| 70 | 8162.5 | 116.6 | 0.197 | 5.985 | 25.52 | 4.57 |
| 69 | 8280.8 | 120.0 | 0.197 | 5.996 | 25.89 | 4.63 |
| 68 | 8402.6 | 123.6 | 0.197 | 6.012 | 26.27 | 4.70 |
| 67 | 8528.0 | 127.3 | 0.198 | 6.033 | 26.67 | 4.77 |
| 66 | 8657.2 | 131.2 | 0.199 | 6.058 | 27.07 | 4.85 |
| 65 | 8790.4 | 135.2 | 0.200 | 6.086 | 27.49 | 4.92 |
| 64 | 8927.8 | 139.5 | 0.201 | 6.125 | 27.92 | 5.00 |
| 63 | 9069.5 | 144.0 | 0.202 | 6.170 | 28.36 | 5.08 |
| 62 | 9215.8 | 148.6 | 0.204 | 6.220 | 28.82 | 5.16 |
| 61 | 9366.9 | 153.6 | 0.205 | 6.279 | 29.29 | 5.24 |
| 60 | 9523.0 | 158.7 | 0.208 | 6.346 | 29.78 | 5.33 |
| 59 | 9684.4 | 164.1 | 0.210 | 6.424 | 30.28 | 5.42 |
| 58 | 9851.3 | 169.9 | 0.213 | 6.512 | 30.80 | 5.51 |
| 57 | 10024.1 | 175.9 | 0.216 | 6.607 | 31.35 | 5.61 |