Mount Hamilton Observing Information
Previous
Four
Hours
Landolt Standards
0h 0m to 3h 59m
Next
Four
Hours

Clicking on a star name produces a finder chart, but note that charts are only available from the mountain server, not from the UCSC mirror site.

Back to Standards Table of Contents Home
StarRA (1950)Dec(1950)V B-VU-BV-RR-IV-I ma(sec/yr) md(arcsec/yr)
HD 315 0 05 10.4 -02 49 376.440-0.145-0.497-0.037 -0.064-0.0100.0020.00
HD 2892 0 29 38.2 00 54 449.3661.3211.4090.692 0.6251.319-0.0010.00
BD -15 115 0 35 49.3-15 16 2310.881-0.190 -0.860-0.095-0.103-0.198

BD -12 134 0 44 32.4-12 08 4011.775-0.294 -1.329-0.088-0.078-0.161

BD -11 162 0 49 44.2-10 56 0211.190-0.081 -1.1380.0500.0950.144

SA 92 336 0 52 27.5 00 31 108.0460.9850.8150.518 0.4650.984-0.001-0.05
SA 92 342 0 52 36.0 00 26 5811.6160.435-0.0400.264 0.2720.536

SA 92 263 0 53 05.5 00 20 0611.7841.0480.8460.564 0.5201.085

HD 5505 0 54 16.8 01 24 399.0011.0780.9550.553 0.5021.0560.0000.00
SA 92 288 0 54 43.1 00 20 3611.6310.8570.4730.489 0.4410.931

F 11 1 01 46.5 03 57 3412.061-0.236-0.978-0.119 -0.141-0.260

SA 93 103 1 50 46.7 00 08 308.8311.1611.1570.585 0.5181.104-0.001-0.02
SA 93 317 1 52 03.6 00 28 1911.5470.489-0.0530.293 0.2960.589

F 16 1 52 04.6 -07 00 4212.405-0.0100.015-0.009 0.004-0.001

SA 93 326 1 52 16.2 00 32 229.5690.454-0.0390.263 0.2650.5280.001-0.04
SA 93 332 1 52 29.0 00 25 309.7890.518-0.0240.296 0.3060.6020.002-0.04
SA 93 333 1 52 31.0 00 31 0212.0060.8290.4340.469 0.4210.891

SA 93 241 1 52 44.4 00 21 519.4000.8530.4250.463 0.4530.916-0.001 -0.01
SA 93 424 1 52 52.1 00 42 0211.6201.0840.9450.553 0.5041.059

HD 11983 1 55 02.5 -07 46 468.1921.5121.8840.807 0.7461.5540.0000.00
HD 12021 1 55 23.7 -02 20 338.874-0.082-0.404-0.042 -0.056-0.098-0.001-0.01
F 22 2 27 39.0 05 02 3412.798-0.055-0.816-0.105 -0.101-0.201

F 24 2 32 30.9 03 30 5212.409-0.199-1.1720.092 0.3620.450

HD 16581 2 37 00.0 01 09 158.195-0.057-0.305-0.025 -0.038-0.0630.0000.02
BD -0 454 a 2 53 22.200 18 538.8951.4261.579 0.7580.6861.4450.0000.00
SA 94 305 a 2 53 22.200 18 538.8891.4231.586 0.7570.6851.4430.0000.00
SA 94 308 2 53 39.6 00 19 158.7430.494-0.0040.290 0.2870.5760.0000.01
SA 94 242 2 54 47.3 00 06 3811.7300.3070.0950.177 0.1860.362

BD -2 524 2 55 07.6 -02 11 4810.307-0.104-0.641-0.050 -0.062-0.111-0.0010.00
SA 94 251 2 55 13.0 00 04 0411.2031.2181.2750.656 0.5861.243

SA 94 702 2 55 38.8 00 58 5711.5951.4161.6140.758 0.6721.431

SA 94 342 2 55 54.6 00 14 179.0410.9930.7160.527 0.4881.0150.000-0.01
HD 21197 3 22 31.6 -05 31 437.8661.1501.1410.686 0.5581.246-0.017-0.77
SA 95 301 3 50 07.0 00 22 2911.2191.2851.2980.692 0.6221.313

SA 95 96 3 50 20.5 -00 08 3310.0140.1470.0680.079 0.0930.172

SA 95 52 3 51 40.1 -00 17 109.5740.5290.0690.307 0.3040.611-0.002-0.03
SA 95 206 3 51 41.5 00 08 368.7370.5020.0150.290 0.2850.575-0.004-0.03
SA 95 132 3 52 17.9 -00 03 2312.0620.4490.3020.259 0.2890.546

SA 95 74 3 52 57.6 -00 17 5611.5291.1270.7020.598 0.5661.163

SA 95 236 3 53 39.5 00 00 0511.4920.7350.1690.421 0.4120.832

Data are from Landolt, A.J. 88, 439, 1983.

F = Feige, HD = Henry Draper Catalogue, BD = Bonner Durchmusterung, SA = Selected Areas, G = Giclas et al. nos. in Lowell Obs. Bulletin proper motion lists
aThese two stars are the same but treated separately by Landolt (1983).


Last modified: Tue Aug 4 17:00:28 PDT 2009